At the top of the Results Pane, click the Save icon . Action Manually uninstall already installed components after you cancelled the installation. Location of log files Most Data Protector log files are located in: Windows Vista, Windows 7, Windows 8, Windows Server 2008, Windows Server 2012: Data_ Protector_program_datalog Other Windows systems: Data_Protector_homelog HP-UX, The default value is 0 (not set). http://awendigital.com/not-connect/cannot-connect-to-the-virtual-machine-try-to-connect-again-hyper-v.html

You did not indicate the type of server, so I can't be ral specific, but, it looks more to me like the INET service is not running on the client systemWindows Problem When adding a new HP-UX client to a Data Protector cell, the following error message may be displayed: /tmp/omni_tmp/packet: you do not have the required permissions to perform this SD The service DP inet service is running and port 5555 is open, but I get the following error every time I try to run this backup. Troubleshooting Guide Chapter 1: About Troubleshooting Data Protector HPE Data Protector (9.07) Page 20 of 115 21.

Cannot Connect To Inet For Getting Filesystem List

Problem If you cancel the Data Protector installation while some components have been already installed, Data Protector does not unistall them. Windows Server 2008, or Windows Server 2012 system fails and reports the following error message: [Normal] Connecting to client computer.company.com... [Normal] Done. [Normal] Installing the Data Protector bootstrap service on Requests from other clients will be denied. Check DNS with omnicheck -dns -host [Servername] on the cell manager.Most problems are DNS Problems.2.

I have noted the contents of the message.From : [email protected] “ LTO_Drive1” Time : ~Cannot backspace segment.(Detail unknown) => backspace segmentFrom : [email protected] “ [Database] : backup ” Time : ~Unexpected Add the DWORD parameter TcpMaxDataRetransmissions and set its value to 0x00000008(8) under the following registry key: HKEY_LOCAL_MACHINESYSTEMCurrentControlSet ServicesTcpipParameters 2. l if the selected tape drive supports encryption, but the medium in it does not support encryption, the data writing operation will be performed in an unencrypted mode. Learn How to Post and More  Community News  Best of the Community Blog  Notebooks Notebook Operating System and Recovery  Notebook Boot and Lockup  Notebook Wireless and Networking  Notebook Audio  Notebook Video,

Storage Optimizer creates soft links in case of Linux operating systems. If you encounter resolution problems when using LMHOSTS file, you get a warning message to check your LMHOSTS file configuration. The reason is an error in the Microsoft Installer upgrade procedure. https://community.hpe.com/t5/Data-Protector-Practitioners/Could-not-connect-to-Data-Protector-inet-process-on-host-client/td-p/4661649 Default: 12:30 P.M..

OB2_CLP_MAX_ENTRIES (Windows systems specific) Sets the number of entries the Windows NTFS Change Log Provider can hold in memory. This means that your clients will accept requests from all systems (any IP address) and will practically not be secured, but you will resolve the excessive logging issue. Data Protector graphical user interface Data Protector provides a cross-platform (Windows and UNIX) graphical user interface. d.

Data Protector Inet Service

OB2_ENHINC_SQLITE_ MAX_ROWS Specifies the maximum number of rows in the enhanced incremental backup database (SQLite on Windows, HP-UX, and Linux systems) that can be stored in the internal memory cache. https://community.hpe.com/t5/Data-Protector-Practitioners/Omniback-could-not-connect-inet/td-p/2736340 Execute the omnidbutil -clear command to set the status of all sessions that are actually not running but are marked as In Progress to Failed. 3. Cannot Connect To Inet For Getting Filesystem List SessionStatusWhenNoObjectToCopy and SessionStatusWhenNoObjectToConsolidate Enable you to control the session status of object copy and object consolidation sessions if there are no objects to copy or to consolidate. Start remote installation of the Data Protector client once again.

To open the configured email client on this computer, open an email window. this contact form To restore AES-256 software encrypted backups created using other Data Protector versions, set this option to 0 (or) remove this option from the omnirc file, and restart the inet daemon on Recovering from power outages The IDB is not reachable after a system recovery Problem The database is capable to recover into a consistent state after such unexpected events as power outages, Action Check for network problems on the remote host and resolve them.

Action To ensure that SOS connections are accepted after the upgrade to Data Protector 9.07 completes, see the HPEData Protector 9.05 Installation Guide (Chapter 6: Maintaining the installation > Security considerations This guide is intended to help you. Nothing in the logs.Any ideas?//Fredric Fredde 0 Kudos Reply All Forum Topics Previous Topic Next Topic 5 REPLIES Kurt Beyers. have a peek here Cannot connect to the client after enabling encrypted control communication on the client Problem After enabling encrypted control communication on the client, you are unable to connect to the client and

There are several reasons why encrypted communication fails to be disabled on clients: Troubleshooting Guide Chapter 2: Troubleshooting Networking and Communication HPE Data Protector (9.07) Page 35 of 115 36. In Results area, the Data Protector Global Options table is displayed, consisting of six columns: l Group - represents the contextual section the option belongs to. Requests from the clients listed in the allow_hosts file will not be logged to inet.log.

Restart the Data Protector GUI.5)The MMD is terminated during the IDB backup or import:If the media management daemon (MMD) is terminated during the IDB backup or import session, the following errors

When copying media, this helps to prevent the target media from running out of space before all data is copied. No insert permission on host. For example, on UNIX systems, variables cannot contain any of the following characters: Space Tab / : * " < > |. Action 1.

Specifically on Windows, restarting is not required when adding or changing entries, only when removing entries (or renaming the file). l The Cell Manager must be able to resolve the names of all clients in the cell. OB2PORTRANGESPEC Limits the range of port numbers that specific Data Protector processes use. Check This Out l Software Release Date, which indicates the release date of this version of the software.

Related tasks Problem If the TCP/IP protocol is not installed and configured on your system, the installation is aborted. Check if your problem is described in the HPE Data Protector Help file or the troubleshooting sections of applicable guides: l To troubleshoot installation and upgrade, see the HPE Data Protector Cannot connect to host: Secure communication protocol negotiation error when trying to establish a connection. Encrypted control communication Using Media Agent installed on a MoM Cell Manager fails Problem In a MoM environment with CMMDB configured and with encrypted control communication enabled, Troubleshooting Guide Chapter 2:

To troubleshoot application integration sessions, see the HPE Data Protector Integration Guide. l if the selected tape drive and the medium in it both support encryption, the data writing operation will be performed in an encrypted mode. It includes the host name details where the device is attached, name of the device, library name, pool name where the media is placed, and device type. By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner

This is most probably a local user. Alternatively, you could encounter the same problem, if one of the cluster nodes is down. The telemetry data files are stored in the following location (see Telemetry data files location): Data_Protector_program_data/config/server/telemetry Telemetry data files location The unpacked telemetry files are saved in the following location (see OB2SANCONFSCSITIMEOUT (Windows systems specific) Sets the timeout for sanconf related operations.

By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner Legal Notices Warranty The only warranties for Hewlett Packard Enterprise Development LP products and services are set forth in the express warranty statements accompanying such products and services.